MicroMag 2900/3900 Data File (Series 0016.002)
Remanence curves:  DCD

INSTRUMENT
Configuration                   VSM
Temperature control             None
Hardware version                0004
Software version                01/29/2013
Units of measure                Hybrid SI
Temperature in                  Kelvin

SAMPLE
Mass                            N/A
Volume                          N/A
Demagnetizing factor            N/A

SETTINGS
Field range                     N/A
Field (command)                 N/A
Moment range                   +100.0000E-06
Averaging time                 +100.0000E-03
Temperature (command)           N/A
Tmprtr difference correction    No
Orientation                     0.000000E+00
Vibration amplitude             1.0
Calibration factor             +5.102630E+00
Operating frequency            +83.00000E+00

MEASUREMENT
Description                    ""
Field (measured)                N/A
Temperature (measured)          N/A
Averages (completed)            N/A
Measured on                     09/04/2023  17:21
Elapsed time                   +98.33537E+00

PROCESSING
Background subtraction          No
Delta-m processing              No
Demagnetizing factor            No
Normalization                   No
Normalization factor            N/A
Offset (field)                  No
Offset (moment)                 No
Pole saturation                 No
Slope correction                No

VIEWPORT
Left                           -100.0000E-03
Right                          +100.0000E-03
Bottom                         -100.0000E-06
Top                            +100.0000E-06
Show X-axis?                    Yes
Show Y-axis?                    Yes

CHARACTERIZATION
Initial slope                   N/A
Saturation                      N/A
Remanence                      +51.48268E-06
Coercivity (direct)             N/A
Coercivity (remanent)          +25.64278E-03
S* (direct)                     N/A
S* (DCD)                       +52.68051E-03

SCRIPT
Include IRM?                    No
Include DCD?                    Yes
Include direct moment?          No
Demagnetize before measuring?   No
Field sequence                  Nonlinear
Initial (non-zero) field       +10.00000E-06
Final field                    +100.0000E-03
Number of points/curve          30
Pause at applied field         +100.0000E-03
Slew rate to applied field     +1.000000E+00
Averaging time                 +100.0000E-03
Saturating field               +100.0000E-03
Pause at saturating field      +1.000000E+00
Saturating field applied        Only once
Slew rate to saturating field  +1.000000E+00
Pause at zero field            +100.0000E-03
Slew rate to zero field        +1.000000E+00
Number of segments              1
Number of data                  30

Segment   Averaging      Initial        Field         Final                    Final 
 Number      Time         Field       Increment       Field         Pause      Index 
             (s)           (T)           (T)           (T)           (s)     
0000001,+100.0000E-03, 0.000000E+00,+10.00000E-06,-100.0000E-03,+100.0000E-03,0000030

                           
    Field       Remanence  
     (T)          (Am)    
+565.2456E-09,+51.48268E-06
-10.56389E-06,+51.45305E-06
-23.67222E-06,+51.43547E-06
-41.27292E-06,+51.42130E-06
-63.18959E-06,+51.40893E-06
-93.75973E-06,+51.38378E-06
-134.4875E-06,+51.34252E-06
-187.1403E-06,+51.28482E-06
-257.1056E-06,+51.20631E-06
-349.0094E-06,+51.08443E-06
-471.2174E-06,+50.93763E-06
-631.6320E-06,+50.72364E-06
-844.8862E-06,+50.44547E-06
-1.126314E-03,+50.06447E-06
-1.498472E-03,+49.56613E-06
-1.988500E-03,+48.89638E-06
-2.637867E-03,+47.97105E-06
-3.490928E-03,+46.73775E-06
-4.623382E-03,+45.03201E-06
-6.117047E-03,+42.66400E-06
-8.097058E-03,+39.27919E-06
-10.71214E-03,+34.38066E-06
-14.15713E-03,+27.10623E-06
-18.71462E-03,+16.31651E-06
-24.73434E-03,+1.853475E-06
-32.69320E-03,-14.38484E-06
-43.20737E-03,-29.46656E-06
-57.09213E-03,-40.96563E-06
-75.41422E-03,-48.03773E-06
-99.69608E-03,-51.51284E-06

MicroMag 2900/3900 Data File ends